Histopathology Tissue Processor Embedding Cassettes

Product Details
Customization: Available
Classification: Biological Diagnostics
Type: Biochemistry Analyzer
Still deciding? Get samples of US$ 12/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Histopathology Tissue Processor Embedding Cassettes
  • Histopathology Tissue Processor Embedding Cassettes
  • Histopathology Tissue Processor Embedding Cassettes
  • Histopathology Tissue Processor Embedding Cassettes
  • Histopathology Tissue Processor Embedding Cassettes
  • Histopathology Tissue Processor Embedding Cassettes
Find Similar Products
  • Overview
  • Exhibition
  • Customer visit
  • Production workshop
Overview

Basic Info.

Model NO.
Tissue Processing Embedding Cassettes
Certification
CE, FDA, EEC, MSDS, ISO13485
Group
Middle-aged and Old
Specimen Stroke
60mm
Specimen Orientation
Horizontal 8, Vertical 8
Section Thickness Setting
60 Micron
Material
Mild Steel and ABS Plastic
Transport Package
Carton Packing
Specification
810*610*590mm
Trademark
Super Accomplish health Technical
Origin
China
Production Capacity
1000000000

Product Description

 

Tissue Processing: Principle, Steps Of Tissue Processing, All machine equipment apply for the tissue processing
Principle of Tissue Processing

  • The technique of getting fixed tissue into paraffin is called tissue processing
  • Tissue processing is designed to remove all extractable water from the tissue, replacing it with a support medium that provides sufficient rigidity to enable sectioning of the tissue without damage or distortion
Fick's Law
  • To equalize concentrations inside and outside blocks of tissue this depends on Fick's Law:
  • the rate of solution diffusion through tissues is proportional to the concentration gradient (the difference between the concentrations of the fluids inside and outside the tissue) as a multiple of temperature dependant constants for specific substances.

Steps Of Processing:1.Dehydration; 2.Clearing;3.Embedding;4.
Pathology Tissue dehydrator

Cup Number
12pcs ( 9pcs reagent cup, 3pcs paraffin cup)
Tissue Protective Cup
7th cup
Single Cup Capacity
1100ml
Single Cup Processing Time
0-24h
Agitation Frequency
0-6times/min, adjustable
Dripping Time
0-60s, adjustable
Processing Basket Capacity
50pcs of dehydration cassette
ProgramStorage
8 sets
Noise
60dB(A)
Power
600W
Power Supply
Standard: 220V 50/60Hz, optional: 110V 50/60Hz
Packing Size
1250*650*700mm
Gross Weight
88kg
Histopathology Tissue Processor Embedding Cassettes

Automatic closed tissue dehydrator,
LCD touch screen
self check function when turn on power
Multiple sets of programmable control programs can be stored

With power-off protection function and built-in UPS system, it can continue to operate for more than 5 hours in case of sudden power failure.

Vacuum Spin Tissue Processor- Vacuum Spin Tissue Processor

1.  DEHYDRATION
•    The first stage of processing is the removal of free unbound water and aqueous fixatives from the tissue components.
•    Many dehydrating reagents are hydrophilic and interact with the water molecules in the tissue by hydrogen bonding.While Other reagents affect dehydration by repeated dilution of the aqueous tissue fluids.
•    Excessive dehydration may cause the tissue to become hard, brittle and shrunken.Incomplete dehydration will impact the penetration of the clearing reagents into the tissue leaving the specimen soft and non-receptive to infiltration.
2.  Clearing
Clearing is the transition/intermediate step between dehydration and embedding.Consists of removal of the dehydrant with a substance that will be miscible with both the embedding medium paraffin and dehydrating agent.
Histopathology Tissue Processor Embedding Cassettes
Laboratory Benchtop 12 stations Automatic fully Pathology Histology baking Linear Vacuum Spin Tissue Processor
1.All 12 station time can be individually programmed using a pin-up timer
2.In-built safety device to protect the tissues in case of power failure
Imported motor and sturdy gear assembly ensures smooth and silent shifting of tissue baskets
3.Thermostatically controlled wax baths with temperature range of ambient to 80 deg C.
4.Continuous rotation of tissue baskets ensures better tissue processing

3.Specification
  1. Short Desc :Spin Tissue Processor 
  2. Tanks: 12 stations , 10 reagent container , 
  3. 2 wax paraffin container 
  4. Option : two basket loading, 3 Wax baths" 
  5. Capcity: 2.3 L for reagent container , 
  6. 1.8 L for wax parafin container" "
  7. Tissue Baskets : Size :Φ 120X100mm 
  8. Number: 1 (2 optinal ), Capacity : max 100 cassettes" 
  9. Temperatuer :45 -85 
  10. Programs: 8 sets 
  11. Vaccuum device pressure : max 0.05 Mpa(approx 0.5 bar) 
  12. Net weight : 80 kg 
  13. Instrument dimension : Φ780 mmX height : 570mm-690mm Nominal voltage : 220 V AC±10% 
  14. Nominal frequency : 50/60Hz   Power : 800W
     
4.Feature
  1. Microcomputer controlling to ensure tissue basket relocating precious
  2. Electricity protection and obstacle protection functions 
  3. Agitation dehydrate mode 10 achieve good dehydrate effect 
  4. Large LCD screen monitoring and showing every step of processing
  5. Timning : delay timing max 99 days 99 hours 59 mins 
  6. Jar processing time : Max 99 hours 59 mins timeing increment : 1 min" 
  7. Constant temperature controlling system adopted on the paraffin jar to ensure high precision of temperature controllong .
  8. Internal surface that provide the good condition for tissue protection 
  9. There are 8 programs selectable 
  10. Battery backup for 8 hours except the paraffin jar 
  11. Addopted with electric lock and passward for specific person use
Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes

Tissue embedding center and cooling plate histology tissue embedding center for lab

Embedding tissues in paraffin wax .Requirements for embedding are as follows:
1.Clean, filtered paraffin wax held at 2-4°C above its melting point.
2.Paraffin dispenser
3.Cold plate to rapidly cool the wax.
4.Moulds in which to embed the tissues.
5.Paraffin wax is dispense automatically from a nozzle into a suitably sized mold.
6.The tissue is oriented in the mold, a cassette is attached.
7.The mold is placed on a small cooling area to allow the paraffin
Tissue Embedding Center & Cooling Plate
* Microprocessor Control for temperature,made in the USA
* The Embedding Module and Cryo Module can be assembled freely
* Flexible heating mechanism, Dual-protection; Safe, Reliable and Energy-Saving
* Fully programmable computer controls allow automatic system start and stop anytime within a week
* Automatic Memory and Restoration: After start, all preset temperature data are automatically stored
* Paraffin Chamber, Paraffin Dispenser, Left and Right Thermal Storage Compartments, and Heating Plate (working area) are
individually controlledOptional:
* Cooling Plate Working Temp.: -20ºC~RT Working Size: 320*300mm
Histopathology Tissue Processor Embedding Cassettes
Product Features:
  1. Temperature control adopts advanced American microprocessor controller, PID five-way independent temperature control, no mutual influence
  2. Simple panel design, function blue LED indication, temperature color-changing LED indication, working status is clear at a glance
  3. International advanced flexible heating concept, overcomes the disadvantage of large temperature difference of traditional heating, fast heating and high precision
  4. Double overheat protection, avoids the shrinkage of paraffin exceeding 70ºC and damaging tissue specimens
  5. With memory and automatic recovery function, the preset temperature is automatically saved after operation
  6. The front and rear double switch design of the freezing table is more convenient and safer to use
  7. The imported valve adjusts the flow of the wax nozzle, which is suitable for various tissue embedding treatments
  8. Large area granite workbench, beautiful and atmospheric, convenient for paraffin cleaning
 
Paraffin Chamber Capacity
3L


Temp.Range of
Forceps Wells


55~70ºC
Paraffin-melting Chamber
Thermal Storage Compartments
Heated Working Areas
Paraffin Dispenser
Temp. Precision
±1%
Material of Work Table
Granite, easy to clean
Paraffin Flow Control
Finger touch plate and optional foot pedal
Power Supply
AC110/220V±10%, 50/60Hz
Consumption
650W
External Size(W*D*H)
525*550*385mm
Package Size(W*D*H)
630*670*520mm
Gross Weight
41kg
Optional Accessory
BK-CPI Cooling Plate
Package Size of BK-CPI (W*D*H)
700*450*530mm
Gross Weight of BK-CPI
37kg
 
Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes



Medical Laboratory Sliding Microtome Tissue Pathological Microtome

Features:
  1. Streamlined molded housing results in attractive appearance and is easy to clean.
  2. Full-automatic sectioning with adjustable speed and three sectioning modes: continuous, step and single.
  3. LED display
  4. Electronic trim function makes it easy to switch from trim and section mode
  5. Specimen retraction mechanism protects specimen from unintended blade damage
  6. Section counting function counts total section pieces and total thickness.
  7. Unit contains a precise micro motion specimen feeding system which uses a micro computer, optical signal and stepper motor to control specimen feeding resulting in more precise specimen feeding. 
  8. Internationally accepted slide mechanism and groove ensures the precision of specimen movement while making the unit free from lubrication and maintenance requirements.
  9. Unit contains a handwheel force balancing system for adjusting the balancing force during sectioning, making rotation even and smooth;
  10. Two safety locking mechanisms on the handwheel; one locks on the top; the other locks at any
position
  1. The disposable blade can move horizontally to avoid the dangers of unintended contact with the blade. Every blade cuts specimen into three equal parts, which ensures the entire use of blade edge
  2. The waste tray collects sectioning debris are easily removed for cleaning
  3. Cassette clamp and C clamp are optional
  4. Specimen orientation on X/Y axes 8°
  5. Alarm to warn of forward or backwards limitation.
  6. Self-diagnostic prompt.
  7. Emergency stop and foot switch (optional)
Histopathology Tissue Processor Embedding Cassettes
1.The specimen retraction protects the specimen and make the section more precise.
2.The red protection guard is to cover the cutting edge when the blade is inserted into the blade holder.
3.Changeable specimen clamp system.
4.For the optimal position of the blade for sectioning the angle of the cutting facet of the blade can be adjusted by moving the blade holder.
Collects the sectioning wastage and can be dismounted easily for cleaning purposes.  
5.Right operation hand-wheel can be locked at any position, providing maximum safety and conve

 
Main Technical Data:
  1. Section thickness range:0.5μm~100μm(3~5um is the best slicing effect)
  2. Section thickness setting:0.5~5μm,in 0.5μm increment
                1. 5~20μm,in 1μm increments
                2. 20~60μm,in 5μm increments
                3. 60~100μm,in 10μm increments
  3. Trimming thickness: 1~600μm
  4. Trimming thickness setting:1~10μm,in 1μm increment ;
                1. 10~20μm,in 2μm increments
                2. 20~50μm,in 5μm increments;
                3. 50~100μm,in 10μm increments;
                4. 100~600μm,in 50μm increments;
  5. Specimen retraction: 10~150μmμm(Can be closed),in 1μm increments ;
  6. Specimen vertical stroke:60mm
  7. Specimen horizontally stroke:25mm
  8. Max specimen size with C clamp (H×W):55mm*45mm
  9. Dimensions (W×D×H):570*510*490mm
  10. Net Weight:34.6kg
Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes

Tissue Water Bath

  • water bath is used for floating out tissue ribbons after sectioning.
  • The trailing end of the ribbon making contact with the water first
  • The temperature of the water in the bath should be 10°C below the melting point of the paraffin.
  • Alcohol or a small drop of detergent may be added to the water allowing the section to flatten out with greater ease
  • 30 seconds are long enough for a ribbon to flatten
Histopathology Tissue Processor Embedding Cassettes
Features:
Quick heating, long lifespan and energy saving, due to the use of a new-type heating element;
Both actual and preset temperatures are displayed;
Automatic memory and restoration functions: After startup, all preset temperature data are automatically stored in the system;
Special black surface material characterized by its strong resistance to abrasion and corrosion.
 
Temp. Range
RTto90°C
Temp. Precision
1°C
Over-Temp. Alarm Range
1~5°C
Environmental Temp. Range
0~40°C
Bath Tank Size(W*D*H)
240*180*55mm
Display
LCD
Power Supply
AC220V±10%» 50/60HZ; AC110V±10%, 60Hz
Consumption
200W
External Size(W*D*H)
345*340*130mm
Package Size(W*D*H)
440*440*220mm
Gross Weight
5kg
 
Features
1.Integrating spreading, baking and roasting slices in one, compact structure (small space occupation), novel shape and easy operation;
2.The film drying box can dry the film at a constant temperature and can accommodate 3 dyeing racks;
3.The louver-style grilling table top has a large capacity (60 slides are actually arranged), easy to put and take out, and the grilling effect is better;
4.High-brightness LCD display, real-time display of sheet spreading and drying sheet temperature, simple and clear;
5.Highly sensitive temperature control integrated unit, high precision and reliable performance;
6.With over-temperature alarm function;
7.Using new heating software, fast heating, uniform heating, small thermal inertia, reliable energy saving;
8.With memory function, automatically retain the set temperature after operation;
9.The work surface is spray-coated, corrosion-resistant.

Tissue Flotation Water Bath & Slide Dryer

Technical Parameters:

Model 

BTH-I

Temp. Range

RTto 90°C

Temp. Precision

2°C

Environmental Temp. Range

0~40°C

Over-Temp. Alarm Range

1~5°C

Drying Area

344*260mm

Bath Tank Size(W*D*H)

304*207*52mm

Display

LCD

Power Supply

AC220V±10%, 50/60HZ; AC110V±10%» 60Hz

Consumption

600W

External Size(W*D*H)

695*400*21 Omm

Package Size(W*D*H)

800*510*320mm

Gross Weight

20kg

Histopathology Tissue Processor Embedding Cassettes
1.Temperature range of water bath: RT - 70°C/RT - 100°C; automatically maintained
2.Automatic memory and restoration functions: After startup, all preset temperature data are automatically stored in the system.
3.Temperature Control Precision:±2°C
4.Dimensions of water bath dish: 210×170×65mm(W×D×H)
5.Dimensions of drying station: 250×108mm(W×D×H)
6.Working Voltage: AC 220V±10% 50Hz (standard model); 7.AC110V±10% 60Hz Power: 400W
8.Dimensions: 310×460×135 mm (W×D×H)
9.Net weight: 6kg
Features:
*Integrate tissue flotation water bath and slide dryer, compact structure and easy operation
*High-brightness LCD display, real-time display of temperature.
*Highly sensitive temperature control integrated unit, high precision and reliable performance.
*With over-temperature alarm function
*Using new heating materials, heating fast, uniform heating, low thermal inertia, energy saving and reliable.
*With memory function. The set temperature is automatically retained.
*Louver-type drying table, easy to operate, better drying effect
*The work surface is sprayed for corrosion resistance.

AUTOMATIC LINEAR TISSUE PROCESSOR

Histopathology Tissue Processor Embedding Cassettes
AUTOMATIC LINEAR TISSUE PROCESSOR
  • Designed for histology and research laboratories
  • Easy-to-use colour touch screen for setting operating parameters
  • 14 stations: 10 for reagents, 4 for paraffin
  • Option for single or double basket run, supporting one or two different protocols
  • Capacity for 150 samples, divided into two baskets of 75 samples each
  • Individually closed containers for all reagents and paraffin, with additional Plexiglas cover to prevent evaporation
  • Active carbon filter included for safe work conditions, preventing odors and air pollution
Capacity and process chamber
Number of processed samples 150 standard cassettes contained in a stainless steel basket (75 per basket, for simultaneous processing of two samples baskets, programmable separately)
Number of paraffin stations 4 but 3 for each basket
Melting time (approximate) 2 hours
Paraffin temperature range 50°C - 75°C ± 1°
Fume extraction system Charcoal filter and smoke
Reagent capacities
Number of stations 14
Number of reagents stations 10
Reservoir volume 1500 ml
Carbon filter 1
Temperature reagents ambient
Temperature of paraffins tanks RT to 85°C
Precision tolerance ±1%
Software
Screen Large touch-screen liquid crystal display (LCD) 14"
Programs 6 freely settable
Time for program step 1 min to 99 hours, 59 minutes
Temperature accuracy ± 1°C
UPS (Optional) in order to carry out the work during power failure
Max. delay time 99 hours, 59 minutes
Technical data
Power supply 220 V ~ 50 Hz or 110 V ~ 60 Hz
Relative humidity 10 to 80%
Maximum power draw 1000 W

Laboratory Educational Single Concave Microscope Blank Glass Slides for Medical

Name

Specification

Corner

Package

7101

Plain, ground edges

90°/45°

50pcs/box, 50boxes/ctn, Measure: 36x18x16cm, G.W./N.W.:14/13KGS  

72pcs/box, 50boxes/ctn, Measure: 44x20x16cm, G.W./N.W.: 20/19KGS

7102

Plain, unground edges

90°/45°

7103

Singe concave, ground edges

45°

7104

Double concaves, ground edges

45°

7105

Single frosted end, ground edges

90°/45°

7105-1

Single frosted end, unground edges

90°

7106

Frosted both ends on one side, ground edges

90°

7107

Double frosted ends, ground edges

90°/45°

7107-1

Double frosted ends, unground edges

90°

7108

Frosted both ends on both sides, ground edges

90°

7109

Colour frosted end, ground edge

90°/45°

7110

Fully frosted on one side, ground edges

90°

7111

Poly-L-lysine Coated slide

90°/45°

7112

Positive charged slide

90°/45°

7113

Silane coated slide

90°/45°

Histopathology Tissue Processor Embedding Cassettes

Histology Tissue Slide Warmer Pathology Tissue Floating Water Bath For Glass Slide

Laboratory microscope slide clips frosted glass slide

Feature

1) 7101: Ground edges

2) 7102: Un-ground edges

3) 7103: Single concave, ground edges

4) 7104: Double concave, ground edges

5) 7105: Frosted one end on one side, ground edges

6) 7105-1: Frosted one end on one side, un-ground edges

7) 7106: Frosted both ends on one side, ground edges

8) 7107: Frosted one end on both sides, ground edges

Histology Tissue Slide Warmer Pathology Tissue Floating Water Bath For Glass Slide

The floating bath and slide warmer machine supports multiple baking modes of oblique insertion and staining rack, and the heating time can be set by oneself.Adopting high-definition color touch screen, the operation is simple and easy to understand, and it is easy to get started quickly.
Histopathology Tissue Processor Embedding Cassettes

The floating bath and slide warmer machine supports multiple baking modes of oblique insertion and staining rack, and the heating time can be set by oneself.
Adopting high-definition color touch screen, the operation is simple and easy to understand, and it is easy to get started quickly.
The slide warmer part has an oblique insertion baking mode makes it easier to pick up the glass slides
Capacity: 60 pcs slides
The tissue floating bath and slide warmer machine temperature range :0 to 99ºC
It's made of special materials,corrosion-resistant.
 
 
Product name
Laboratory tissue floating bath and slide warmer machine
Capacity
60pcs slides
Temperature range
0-99ºC
Feature
It has multifunctionality and is suitable for various sheet processing needs.

Histopathology Laboratory Equipment Cryogenic CE Medical Cryostat Microtome
Features:
1.
Control System:
1) Fully automatic computer control, LCD displays 4 temperatures on the same screen
2) Automatic slicing and automatic trimming; manual slicing and manual slicing, switch at will.
3) The number of slices can be set according to the slicing needs.
4) The trimming thickness and slice thickness can be adjusted at any time.
5) LCD screen hardware dynamic display function displays the working status of all hardware. The dynamic display hardware items include: A compressor; B compressor; lighting; ultraviolet light; defrost; motor forward and backward; cold knife refrigeration, Special refrigeration of the cold stage. (These hardware signs are dynamically displayed at the bottom of the LCD screen) so that the operator can fully grasp the operating status of the instrument.
And there is a timing display every time the compressor is about to start working.
6) The sample head has a retraction function. The retraction distance can be set arbitrarily according to the needs of the operator.
7) Has counting function.
2. Cooling System
1) Five-point refrigeration: A dual-compressor refrigeration system with five key refrigeration points: freezing head, freezing knife, freezing box, and double freezing tables. The freezing head can set different sectioning temperatures according to different tissues.
2) Refrigeration speed: No pre-cooling is required. It will enter the freezing state within 30 minutes of being turned on. It can be shut down after use. It is an energy-saving product.
3) Health protection: The temperature inside the freezer does not need to be too low. Excellent frozen sections can be cut. Avoid the vicious irritation of cold hands due to low temperature.
3. System protection
The rapid cooling system can be shut down manually at any time. After 8 hours of operation, if you forget to turn it off, the system will automatically shut down the rapid cooling system and enter a dormant state.
4. Defrost system
Auto defrost and manual defrost functions. You can set (1) defrost interval (2) defrost time by yourself. It can also be defrosted manually at any time (3). You can set the interval according to the temperature in your location. Defrost can also be turned off at any time, and it can enter the freezing state ten minutes after being turned off. No impact on work.

5. Mechanical structure
Excellent mechanical structure, imported vertical cross rolling bearings determine the stability of the machine, the machine core is a closed structure, maintenance-free. Excellent mechanical properties, accurate footage, smooth and reliable slices, superior and convenient anti-curling function.
6.Cleaning function: It has ultraviolet disinfection function; the freezer has a drain pipe for easy cleaning.
7. other
1) Steel knives and disposable blades are universal. (It is not that steel knives and disposable blades are universal, only disposable blades can be used, and the knife holder moves left and right)
2) The editing function is completed outside the box.
3) Tool retraction, tool advance, limited position, divided into fast and slow speeds.
4) Tissue heat-absorbing device: cooperates with the cooling stage to cool the tissue up and down at the same time, speeding up tissue freezing.
Adjustable slicing speed
5) The number of slices can be set according to the situation. You can stop slicing at any time!
6) Has real-time clock mode

 

Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes
Exhibition

We take part into the MedtecChina Canton Fair (The China Import and Export Fair) exhibition every year ,hope one day we can meet each on the fair
Histopathology Tissue Processor Embedding Cassettes

 
Customer visit

Customer review our Fully Automated Tissue Steiner  workshop,We were welcome all of our customer to visit our company to review and test the Fully Automated Tissue Steiner for Organisms, Medical, Chemistry,Our business vision was :long term business ,win-win for the future
 

Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes

 

 
Production workshop

Our main products were: Centrifuge Machine,Centrifuge Tube,Tube Rack,Tube Holder,Gel Heating Machine,Ultrasonic Cleaner,Magnetic Stirrer,Blood Presssure Monitor,Oxygen Saturation Monitor Pill Organizer,Stethoscope,Digital Thermometer,UPS Lab Stand,Lab Serving Cart,Lab Vortex Mixer,Rotator Vortex Mixer,Lab Powder Mixer,Plastic Dropper Pipettes Stainless Steel Trays,Pipettors,Drying Rack For Lab Glassware And Bottles,Orbital Shaker,Lab Steam Sterilizer,Oven Burnout Furnace,Wheel Rollator Walker
Histopathology Tissue Processor Embedding Cassettes
Histopathology Tissue Processor Embedding Cassettes

The supplier and the customer was togeher for the future ,both parties should be in win-win situation ,so we were looking forwarder to hold hand by hand for bright future.

1.sample test before PO release to test our equipment fit your site requirement.
2.You were welcome to visit our company anytime you like.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier