Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | One Year |
Still deciding? Get samples of US$ 1000/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Max. Speed
|
4000rpm
|
Max. RCF
|
2200×g
|
Max. Capacity
|
4×500ml
|
Time Range
|
0~100h
|
RPM/RCF Convert
|
Yes
|
Noise (dB)
|
≤ 58
|
Acc/Dec
|
10 Kinds
|
Speed Accuracy
|
±20r/min
|
Voltage(V/Hz)
|
AC 220V/110V 50HZ/60HZ
|
Size (W x D x Hmm)
|
720×710×410mm
|
Net Weight(Kg)
|
130KG
|
Certificates
|
CE,ISO & Calibration report are available
|
Features:
* The whole machine adopts steel structure and stainless steel centrifugal chamber.
* Embedded microprocessor control, DC brushless motor drive, maintenance-free, smooth operation.
* Push-button programming design, digital tube display, real-time display of all operating parameters, intuitive and simple operation.
* Alarm monitoring function, real-time monitoring of lock and motor status, safe and reliable operation.
* Centrifugal speed, centrifugal time and other parameters can be set, and real-time display of centrifugal force.
* Equipped with a variety of Angle rotors, to meet different test requirements, a multi-purpose machine.
Rotor Type | Max Speed | Max RCF | Notice | |
48*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 2952*g | / |
72*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 2808*g | / |
48*5/7mlBlood collection tube | Swing Rotor | 4000r/min | 2952*g | 48*2/3/4mlBlood collection tube |
80*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 2808*g | / |
96*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 3104*g | / |
120*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 3327*g | / |
148*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 3327*g | / |
160*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 3274*g | / |
16*10/15ml | Swing Rotor | 4000r/min | 2957*g | 16*15mlConical |
16*2/3/4mlBlood collection tube | ||||
16*5/7mlBlood collection tube | ||||
16*5ml | ||||
16*7ml | ||||
24*10/15ml | Swing Rotor | 4000r/min | 2952*g | 24*15mlConical |
24*2/3/4mlBlood collection tube | ||||
24*5/7mlBlood collection tube | ||||
24*5ml | ||||
24*7ml | ||||
32*10/15ml | Swing Rotor | 4000r/min | 2952*g | 32*15mlConical |
32*2/3/4mlBlood collection tube | ||||
32*5/7mlBlood collection tube | ||||
32*5ml | ||||
32*7ml | ||||
36*10ml | Swing Rotor | 4000r/min | 2862*g | / |
64*10/15ml | Swing Rotor | 4000r/min | 3220*g | / |
64*10mlBlood collection tube | Swing Rotor | 4000r/min | 2952*g | / |
4*50ml | Swing Rotor | 4500r/min | 3747*g | 4*50mlConical |
4*1.5ml | ||||
4*5ml | ||||
4*10ml | ||||
4*15ml | ||||
4*20ml | ||||
8*50ml | Swing Rotor | 4000r/min | 2952*g | 8*50mlConical |
8*1.5ml | ||||
8*5ml | ||||
8*10ml | ||||
8*15ml | ||||
8*20ml | ||||
4*100ml | Swing Rotor | 4500r/min | 3894*g | 4*2/3/4mlBlood collection tube |
4*5/7mlBlood collection tube | ||||
8*100ml | Swing Rotor | 4000r/min | 3077*g | 8*2/3/4mlBlood collection tube |
8*5/7mlBlood collection tube | ||||
4*250ml() | Swing Rotor | 4000r/min | 2780*g | 48*1.5/2ml |
40*2/3/4/5/7mlBlood collection tube | ||||
24*10ml Conical | ||||
28*10ml | ||||
20*15ml | ||||
4*50ml | ||||
8*50ml Round | ||||
4*100ml | ||||
4*250ml(Conical) | Swing Rotor | 4000r/min | 3578*g | / |
4*300ml | Swing Rotor | 4000r/min | 3220*g | / |
4*500ml() | Swing Rotor | 4000r/min | 3130*g | 48*2/3/4/5/7mlBlood collection tube |
36*10ml | ||||
36*15ml | ||||
12*50mlRound | ||||
16*50mlRound | ||||
16*50mlConical | ||||
4*500ml(Conical) | Swing Rotor | 4000r/min | 3578*g | / |
4*750ml | Swing Rotor | 4000r/min | 3399*g | / |
80*2/3/4/5/7m Swing Rotor | Swing Rotor | 4000r/min | 3220*g | / |
108*2/3/4/5/7m Swing Rotor | Swing Rotor | 4000r/min | 3399*g | / |
96*10mlBlood collection tube | Swing Rotor | 4000r/min | 3211*g | / |
120*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 3327*g | / |
148*2/3/4/5/7mlBlood collection tube | Swing Rotor | 4000r/min | 3327*g | / |
2*2*96 | Swing Rotor | 4000r/min | 2361*g | / |
4*2*96 | Swing Rotor | 4000r/min | 2987*g | / |
12*20ml | Angel rotor | 5000r/min | 3516*g | 12*1.5ml |
12*5ml | ||||
12*10ml | ||||
12*15ml | ||||
12*15ml | Angel rotor | 5000r/min | 3354*g | 12*1.5ml |
12*2/3/4mlBlood collection tube | ||||
8*15/20ml | Angel rotor | 5000r/min | 2655*g | 8*1.5ml |
8*2/3/4mlBlood collection tube | ||||
24*10ml | Angel rotor | 5000r/min | 3354*g | 24*1.5ml |
24*2/3/4mlBlood collection tube | ||||
18*10ml | Angel rotor | 5000r/min | 3354*g | 18*1.5ml |
18*2/3/4mlBlood collection tube | ||||
12*10ml | Angel rotor | 5000r/min | 3354*g | 12*1.5ml |
12*2/3/4mlBlood collection tube | ||||
12*10/15ml | Angel rotor | 6000r/min | 5111*g | 12*2/3/4mlBlood collection tube |
12*5/7mlBlood collection tube | ||||
12*5ml | ||||
12*7ml | ||||
12*15mlConical | ||||
6*50ml | Angel rotor | 5000r/min | 3904*g | 6*50mlConical |
6*1.5ml | ||||
6*5ml | ||||
6*10ml | ||||
6*15ml | ||||
6*20ml |
Benchtop Centrifuges | Microcentrifuges | High-Speed Centrifuges |
Benchtop centrifuges are compact and versatile, 1.Suitable for a variety of routine laboratory applications. 2.They are available in several models, including microcentrifuges, low-speed, and high-speed versions, catering to different sample volumes and types. 3.Common uses include cell culture, blood sample separation, and protein precipitation. |
Microcentrifuges are designed for small-volume samples, 1.Typically accommodating 1.5 to 2.0 mL tubes. 2.They are essential in molecular biology labs for applications such as DNA/RNA extraction, PCR sample preparation, and enzyme assays. 3.These centrifuges offer high speed and quick acceleration/deceleration times. |
1.High-speed centrifuges are capable of reaching speeds up to 30,000 RPM, making them suitable for pelleting cells, nucleic acids, and subcellular fractions. 2.They are often used in research laboratories for more demanding applications that require higher g-forces and faster processing times. |
Ultracentrifuges | Refrigerated Centrifuges | Clinical Centrifuges |
1.Ultracentrifuges can reach speeds exceeding 100,000 RPM and are used for separating very small particles such as viruses, ribosomes, and macromolecules. 2.They are crucial in fields like molecular biology, biochemistry, and nanotechnology. 3.Ultracentrifuges require specialized rotors and offer precise temperature control. |
1.Refrigerated centrifuges maintain samples at low temperatures during centrifugation, preventing heat-sensitive samples from degrading. 2.They are essential in clinical laboratories, biochemistry, and molecular biology for processing temperature-sensitive samples like proteins, nucleic acids, and blood components. |
1.Clinical centrifuges are designed for routine diagnostic applications in medical laboratories. 2.They are used for blood and urine sample preparation, separation of blood components, and other clinical applications. 3.These centrifuges are user-friendly and often come with pre-programmed settings for common protocols. |
Speed and g-Force | Rotor Compatibility | Capacity |
1.The speed (RPM) and relative centrifugal force (g-force) are critical factors in choosing a centrifuge. 2.Higher speeds and g-forces enable the separation of smaller particles and faster processing times. 3.Ensure the centrifuge meets the specific speed and g-force requirements of your applications. |
1.Different applications require different types of rotors (fixed-angle, swing-bucket, vertical). 2.Verify that the centrifuge is compatible with the rotors you need. 3.Additionally, consider the ease of rotor installation and the availability of rotors for future expansion. |
1.Centrifuge capacity, in terms of the number of tubes and their volume, is a vital consideration. 2.Ensure the centrifuge can handle the volume and number of samples you typically process. 3.High-capacity models are beneficial for labs with high-throughput needs. |
Temperature Control | 5. User Interface and Safety Features | |
1.For applications involving temperature-sensitive samples, refrigerated centrifuges with precise temperature control are essential. 2.Look for models that offer a wide temperature range and accurate temperature maintenance during runs. |
1.Modern centrifuges come with advanced user interfaces, including digital displays, programmable settings, and automatic rotor recognition. 2.Safety features such as imbalance detection, lid locking systems, and emergency stop functions are also crucial for ensuring safe operation. |
Customer review our Laboratory Centrifuge Machine workshop,We were welcome all of our customer to visit our company to review and test the Centrifuge Machine for Organisms, Medical, Chemistry,Our business vision was :long term business ,win-win for the future
Warehouse and stroage for the medical Centrifuge Machine,the temperature should be control within 18-25° for all equipment and test machine ,all the record can trace within 3 years.
The maintain and repair guarantee for the Centrifuge Machine workshop was the key to the business ,when a customer bought a machine from us ,the guarantee was the most importance things customer concern.we sent out technical service team to oversea customer site for the maintain and repair for our customer .Our service for the lab equipment was not stop after the Centrifuge Machine sold ,it was the start for our company and your company for win win situation .You use the Centrifuge Machine we take care of the rest.
We take part into the MedtecChina Canton Fair (The China Import and Export Fair) exhibition every year ,hope one day we can meet each on the fair
The supplier and the customer was togeher for the future ,both parties should be in win-win situation ,so we were looking forwarder to hold hand by hand for bright future.