Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent

Product Details
Customization: Available
Classification: Imaging Diagnostic Equipment
Type: Hematology Analyzer
Still deciding? Get samples of US$ 10000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
  • Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
  • Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
  • Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
  • Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
  • Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Find Similar Products
  • Overview
  • Product Parameters
  • Production workshop
  • Customer visit
  • Packing and loading
  • After market service
  • Exhibition
  • Our vision
Overview

Basic Info.

Model NO.
Hematology Analyzer
Group
Middle-aged and Old
QC Control
X-B, L-J, X, SD, CV%
Refrence Value Setting
Male, Female, Children, Neonate
Work Mode
Single Channel + Unique Hemoglobin Test System
Temperature
18′c - 30′c, Wet < 10-90%
Transport Package
Carton Packing
Specification
810*610*590mm
Trademark
Super Accomplish health Technical
Origin
China
Production Capacity
1000000000

Product Description

 

 

This 5-part auto hematology analyzer is applicable for detecting the parameters of WBC, RBC, PLT, HGB, etc. (see Section 3.2. Parameters for details) in anticoagulated venous whole blood or capillary blood, as well as WBC 5-part differential analysis and WBC counting
General Features 
7 inch touch screen and keypad 2000 hours' long-life halogen lamp Permanent quartz flowcell Reaction cur ve real time display Thermal printer, auto&manual print Flowcell & cuvette modes Less and easy maintenance 
 
Test Items 
Liver ALT, ALP, GGT, TP, Aib, TBIL, DBIL Heart LDH, CK, CK-MB, AST, A-HBDH Lipids CHO, TG, HDL_C, LDL_C Lipoprotein Apo A1, Apo B, Lp(a) Kidney BUN, CRE, UA Other CO-CP, AMS, LIP, GLU, IgG, IgM, C , C , CRP
Specifications
Parameter
Precision
Linear Range
Contamination Rate
WBC
≤2.0% (3.5-15.0×109)/L
(0-300.0×109)/L
≤0.5%
RBC
≤1.5% (3.0-6.0×1012)/L
(0.10-8.00×1012)/L
≤0.5%
HGB
≤1.5% (100-180) g/L
(0-250) g/L
≤0.6%
MCV
≤1.0% (70-120)fL
-
-
PLT
≤4.0% (150-500×109)/L
(0-4000×109)/L
≤1.0%
 
 

 

Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
 
Product Parameters
 

Model

SA-3200

Throughput

60 samples/hour

Principle

Impedance for WBC differentiation and WBC/RBC/PLT count; Colorimetric method for HGB

Channels

2

Parameters

21 parameters(including WBC, Mid#, Lym#, Gran#, Mid%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV,PDW,PCT, P-LCR, P-LCC)

Histograms

3 histograms (including WBC, RBC, PLT histograms)

Sample Volume

Whole blood: 12μl, Prediluted: 20μl

Calibration

Manual, auto calibration

Counting Modes

Venous, capilary, prediluted

Printing Model

Auto print, manual print

LIS

Support Bi-directional LIS

Language

Chinese, English, Spanish, French, Russian, Ukrainian

Reagent

Diluent 10L, Hemolytic agent 250ml, Probe cleanser: 50ml

Data Input

9.7-inch touch screen, mouse, keyboard (optional)

Output

Internal printer, support external printer

Printer paper

57*30mm

Interface

4 USB ports, network port,RS232 serial port.

Storage

100,000 results with histogram

Unclog

High voltage burn, reverse high-pressure flush

Work Temperature

15-30°C

Power Supply

100~240 AC, 50/60Hz, 150VA

Relative Humidity

30~85%

Atmospheric Pressure

70.0kPa-110.0kPa

Carry-over rate

Parameter

WBC

RBC

HGB

PLT

CV

≤ 1.5%

≤ 1%

≤ 1%

≤ 3%

Background

Parameter

WBC

RBC

HGB

HCT

PLT

Background

≤ 0.3×109/L

≤ 0.03×1012/L

≤ 1 g/L

≤ 0.5%

≤ 10×109/L

Linearity

Parameter

Measurement range

CV

WBC

(0.5~10.00×109)/L
(10.10~99.9×109)/L

(±0.5×109)/L
±5%

RBC

(0.05~1.00×1012)/L (1.01~9.99×1012)/L

(±0.05×1012)/L
±5%

HGB

(2~70g)/L
(71~300.0g)/L

(±2.0g)/L
±2%

PLT

(10~100×109)/L
(101~999×109)/L

(±10.0×109)/L
±8%

Precision

Parameter

Repeatability

Measurement range

WBC

≤ 6.0%

(3.5~9.5×109)/L

RBC

≤ 3.0%

(3.8~5.8×1012)/L

HGB

≤ 2.5%

(115~175g)/L

PLT

≤ 10.0%

(125-350×109)/L

HCT

≤3.0%

35%~50%

External Size(W*D*H)

295*467*418mm

Packed Size(W*D*H)

Instrument: 404*564*616mm; Reagent: 340*340*340mm

Net weight

19 KG

Gross weight

Instrument: 31KG; Reagent:13Kg

Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent

 
 
 
 
 
 
Production workshop

The production of the Auto Hematology Analyzer machine introduce
1.Start by the blanking process for the metal part

Normally the house of the Auto Hematology Analyzer medical was made by the steel or stainless steel of type as 316
The part was beginning as the blanking
1.Laser blanking machine capacity :8000*2000*10mm 
2.We had about 15 pcs of the laser cutting machine in blanking workshop ,name from No1 to No 15,
3.6S fully carry out in our workshop according to the iso13485,
4.All of the raw material can be Traceability
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
2.Bending process for CO2 Incubator Shakingmachine by the press break bending machine 
The press brake machine is a powerhouse in the metal fabrication industry, providing an efficient and successful method to bend sheet metal into different forms
To form the metal part into the shape we need ,the first part was by the bending press and the bending die
 
Stainless Steel :Provides great strength and resistance to corrosion, but its greater spring back the ability to revert to its original shape after bending means that it must be handled carefully. 

 
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
3.Progressive die metal stamping workshop for Autoclave machine part.
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
High Temperature Autoclave Machine need the bracket for the motor and metal stamping part for the housing and electric connect part,The progressive die stamping can give out the huge volume and low cost for the Surgical Instruments Autoclave Steam Stainless Steel Sterilization Machine Lab Equipment machine spare metal part.
4.Welding workshop for the digital shaker incubator
The Medical Sterilization machine need a lot of welding ,to imporve the capacity and welding quality we introduce the welding robot machine instead of labor human welding
1.QTY of the welding robot :23pcs
2.Capacity of the welding robot :500A
3.Work station:2000*1500mm
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
5.Plastic injection workshop for the Benchtop Steam Autoclave machine
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Plastic part was one part of the  Horizontal Stacked CO2 Incubator Shaker
We had about 10 sets of the plastic injection work for the Lab  Horizontal Stacked CO2 Incubator Shaker
1.The capacity for plastic injection machine was :1000*850*750mm
2.The max ton for plastic injection machine was 1000T
6.The spare part Warehouse for the benchtop Stainless Steel 5 Part Cbc Auto Hematology Analyzer
The 6S was fully carry out in our warehouse with the ERP system 
1.We need to know how many part in our warehouse
2.We need to anticipate the part when to full fill in for all the benchtop Autoclave with Drying Function Water Storage Tank 
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
7.CNC machining for the benchtop fully automated 5 part veterinary hematology analyzer
 
8.co2 incubator stamping ,welding ,rolling Production process on site,the container of the co2 incubator Machine need the vacuum and seal can bear though high pressure 

9.Electric part assemble to the  Multifunction Steam Sterilization Machine workshop,the plc or the other computer control part connect to the machine before move to the next production procss.
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
10.Test workshop for the  Multifunction Steam Sterilization Machine  
Customer visit

Customer review our Laboratory co2 incubator Machine workshop,We were welcome all of our customer to visit our company to review and test the co2 incubator for Organisms, Medical, Chemistry,Our business vision was :long term business ,win-win for the future

Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Packing and loading
The over sea customer always concern about the packing and loading for the Steam co2 incubator Machine,we cant bear the lost for tiny mistake for the Vacuum Steam Machine machine ,one mistake will cause the machine broken or cant work .
From the packing for Laboratory Medical Sterilization Machine to the container loading detail show as below 

Warehouse and stroage for the medical Medical Sterilization Machine,the temperature should be control within 18-25° for all equipment and test machine ,all the record can trace within 3 years.
 

Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent

 

After market service

The maintain and repair guarantee for the Medical Sterilization Machine workshop was the key to the business ,when a customer bought a machine from us ,the guarantee was the most importance things customer concern.we sent out technical service team to oversea customer site for the maintain and repair for our customer .Our service for the lab equipment was not stop after the Vacuum Steam Machine Machine sold ,it was the start for our company and your company for win win situation .You use the Vacuum Steam Machine Machine we take care of the rest.

Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Exhibition

We take part into the MedtecChina Canton Fair (The China Import and Export Fair) exhibition every year ,hope one day we can meet each on the fair
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent

Our vision

The supplier and the customer was togeher for the future ,both parties should be in win-win situation ,so we were looking forwarder to hold hand by hand for bright future.

Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent
Open System Cbc Machine Hematology Analyzer Full-Auto Hematology Analyzer for Mindray and Cypress Reagent



Introduction
The Automatic Hematology Analyzer is an in vitro diagnostic device that used for quantitative analysis of blood cells in medical
laboratories, and it can realize three classifications of the count results of white blood cells. This analyzer is a clinical
inspection instrument for screening. When making a clinical judgment based on the analysis results, the doctor should take the
clinical examination results or other test results into consideration. This analyzer is suitable for the detection of white blood
cells, red blood cells, platelets, hemoglobin and other parameters and counting of white blood cells into three classifications.
Function

l Automatic storage of test results, review and print all parameters in test results;
l Color touch screen, all parameters and histograms can be displayed in the same screen;
l Support the expansion of external devices such as mouse, keyboard and printer;
l Optical five reference ranges: newborn, children, adult women, adult men, and general use;
l Multiple clogging elimination methods: high-pressure burning jewel hole, high-pressure reverse rinsing and soaking;
l Automatic cleaning of sample probe;
l By VGA interface, external projector or external display screen can be connected;
l Chinese and English system language;
l Built-in thermal printer, serial port printing and other printing methods;
l With quality control management and calibration management function;
l Use the cyanide-free SFT method (environmentally friendly) to measure hemoglobin;
l Floating boundary algorithm and histogram abnormal prompt function.

Performance

l Test parameters: WBC 3-part differential counting, 23 parameters (including WBC, RBC, PLT color histogram);
l Measurement principle: counting by electrical impedance method, colorimetric method to measure HGB;
l Quality control method: L-J, automatic drawing and printing of quality control charts;
l Sample volume: trace detection, 10μL peripheral blood or anticoagulant blood, pre-dilution mode 20μL;
l Precision: WBC (white blood cell) CV≤4.0%, RBC (red blood cell) CV≤2.0%, HGB (hemoglobin) CV≤2.0%, PLT (platelet) CV≤8.0%, MCV
(average red blood cell volume) CV≤3.0% ;
l Accuracy: the allowable relative deviation range: WBC≤±15%, RBC≤±6.0%, HGB≤±6.0%, PLT≤±20.0%, HCT (hematocrit)≤±9.0%;
l Blank count: WBC≤0.5×109/L, RBC≤0.05×1012/L, HGB≤2.0g/L, PLT≤10.0×109/L;
l Carry-over: WBC≤3.5%, RBC≤2.0%, HGB≤2.0%, PLT≤5.0%;
l Linearity deviation: WBC≤±5%, RBC≤±5%, HGB≤±3%, PLT≤±10%;
l Related coefficient: WBC≥0.990, RBC≥0.990, HGB≥0.990, PLT≥0.990;
l Display: color LCD touch screen;
l Detection channel: dual channel;
l Test speed: 35 (or 60) specimens/hour, continuous working for 24 hours;
l Data storage: It can automatically store more than 30,000 groups of complete results (each result has three histograms);
l Interface: RS232 interface, VGA interface;
l Power supply: ~100V-240V; 50/60Hz.

Accessories

l Mouse
l Thermal print paper
l Power cord
l Grounding cable
l Serial cable
l Pipe assembly (for Diluent, Hemolytic agent,Waste liquid respectively)
l Touch pen
l User manual
l Key of device side board

Physical characteristic
Dimension: 433mm(L)×300mm(W)×430mm(H)
Weight: 19kg
Operating Environment:
Temperature: 18ºC~25ºC
Relative humidity: ≤80%
Atmospheric pressure: 86.0kPa~106.0kPa
Storage Environment:
Temperature: -10ºC~55ºC
Relative humidity: ≤93%
 Atmospheric pressure: 50.0kPa~106.0kPa

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier