Model
|
BK-2328
|
Section Thickness Range
|
1-100μm
|
Trimming Thickness Range
|
10-400μm
|
Chamber Temp. Range
|
-10ºC to -40ºC
|
Specimen Head Temp. Range
|
-10ºC to -40ºC
|
Time to The Lowest Temperature
|
60min
|
Lowest Temp. of Refrigerating Table
|
-45ºC
|
Lowest Temp. of Peltier Together with Refrigerating Table
|
-60ºC
|
Max Specimen Size
|
55*60mm
|
Specimen Vertical Stroke
|
72mm
|
Specimen Horizontal Stroke
|
22mm
|
Electric Coarse Feed
|
Rapid 0.7mm/s, slow 0.35mm/s
|
Power Supply
|
Standard: 220V 50/60Hz, optional: 110V 50/60Hz
|
Power
|
500W
|
External Size
|
770*840*1190mm
|
Packing Size
|
850*940*1400mm
|
Gross Weight
|
165kg
|
Model
|
|
Range of the thickness of slice
|
|
Setting thickness of slice ranges
|
|
2~10 μm increment 1 μm
|
|
10~20 μm increment 2 μm
|
|
20~60 μm increment 5 μm
|
|
Tolerance
|
|
Minimum setting value
|
|
Specimen horizontal feeding
|
|
Specimen stroke Length
|
|
Specimen stroke horizontal
|
|
Maximum section of slice
|
|
Specimen adjust angle
|
|
Dimension
|
|
Weight
|
|
Refrigerating range to set: room temperature ~ -60ºC |
Section thickness: 0~100μm |
Minimum division value: 0.5μm |
Trimming range: 0~600μm |
Specimen horizontal shifting distance: 25mm |
Specimen vertical shifting distance: 60mm |
Sectioning angle adjustable: 10° |
Freezing positions: 10~15 |
Temperature reachable: |
freezing head -50ºC |
freezing table -45ºC |
freezing knife -35ºC |
freezing chamber -25ºC±5 |
Voltage: 220V |
Power: 800VA |
Voltage: 220V |
Weight: 120kg |
The production of the Automatic Pathological Tissue Microtome machine machine introduce
1.Start by the blanking process for the metal part
Customer review our Fully Automated Tissue Steiner workshop,We were welcome all of our customer to visit our company to review and test the Fully Automated Tissue Steiner for Organisms, Medical, Chemistry,Our business vision was :long term business ,win-win for the future
Warehouse and stroage for the medical Medical Sterilization Machine,the temperature should be control within 18-25° for all equipment and test machine ,all the record can trace within 3 years.
The maintain and repair guarantee for the Medical Sterilization Machine workshop was the key to the business ,when a customer bought a machine from us ,the guarantee was the most importance things customer concern.we sent out technical service team to oversea customer site for the maintain and repair for our customer .Our service for the lab equipment was not stop after the Vacuum Steam Machine Machine sold ,it was the start for our company and your company for win win situation .You use the Vacuum Steam Machine Machine we take care of the rest.
We take part into the MedtecChina Canton Fair (The China Import and Export Fair) exhibition every year ,hope one day we can meet each on the fair
The supplier and the customer was togeher for the future ,both parties should be in win-win situation ,so we were looking forwarder to hold hand by hand for bright future.
1. Automation: automatic trimming, automatic sectioning, manual trimming, and manual sectioning available.
2. Control system: computer full-automatic control, 04 temperatures can be displayed in the same LCD.
3. Refrigeration speed: no need for pre-cooling, and sectioning can be done while the machine starts for 10 minutes.
4. 05 points refrigeration: freezing head, freezing knife, freezing chamber, double freezing tables.
5. Freezing head: different sectioning temperatures can be set as per different tissues.
6. Functions: withdrawal, sectioning speed adjustment, hardware dynamic state display.
7. Functions: automatic/manual defrosting, lighting, disinfection with ultraviolet.
8. Functions: freezing chamber with sewer pipe, which is convenient to clean, compressor has a function of countdown, counting, and clock display duly.
9. Mechanical system: bearings imported, accurate machining, steady mechanism, tight structure of mechanical cores, free maintenance.
10. The machine is assembled with an anti-curl plate, so sectioning is smooth and reliable.
11. Rapid refrigerating system: if the power off was forgotten after working for 08 hours, the system will directly enter a dormant state.
12. Steel knives are in common use with disposable knives.
13. Operation modes: electric sample feed, and withdrawal; there are quick and slow gears.
14. Heat absorption device for tissues: it will be mated with a freezing table, meanwhile the upper and the lower will be refrigerated at the same time so that freezing speed is fast.
15. Speed of sample feed and withdrawal: there are quick and slow gears.
16. Temperature does not need too low so that stimulation of hands due to lower temperature can be avoided.